STONE PANELS, INC.
100 South Royal Lane
CARROLLTON, TEXAS 75006
PHONE: (469) 635-5000
(800) 328-6275
FAX: (469) 635-5555
GUIDE SPECIFICATIONS
SECTION 07420 - NATURAL STONE REINFORCED PANELS (EXTERIOR)
SECTION 09452 - NATURAL STONE REINFORCED PANELS (INTERIOR)
PART 1 - GENERAL
1.01 WORK INCLUDED:
- Furnish all labor, materials, tools, equipment and services for installing composite
stone panels consisting of natural stone veneer bonded by high strength epoxy impregnated
fiber glass mesh to aluminum honeycomb reinforcing.
- Furnish and install all supplementary anchors and accessories as shown on drawings for a
secure and complete installation.
1.02 RELATED WORK SPECIFIED ELSEWHERE:
- Dimensional Stone: Section 04400
- Cold Formed Metal Framing: Section 05400
- Insulation and Firesafing: Section 07200
- Flashing and Sheet Metal: Section 07620
- Joint Sealant: Section 07920
- Gypsum Sheathing: Section 09250
1.03 SUBMITTALS
- Product Data: Submit specifications, installation instructions and recommendations from
manufacturer.
- Shop Drawings: Submit shop drawings showing alignments, joint locations and sizes,
supports, attachment devices, accessories, complete pattern layout plan, corner detail and
installation details.
- Samples: Submit a minimum of one sample not less than 6" x 6" size for each
stone type required.
- Test Data: Submit summary of test conducted verifying performance capabilities.
1.04 QUALITY ASSURANCE
- Manufacturer Qualifications:
The manufacturer shall have a minimum of 10 years
demonstrated capability to produce composite natural stone veneer reinforced panels of the
quality and scope required, shall have completed independent laboratory tests verifying
performance capabilities, and shall be able to furnish a list of previous jobs of a
similar size plus references.
1.05 WARRANTY
- The manufacturer shall provide a 10 year warranty that the panels will be free from
defects in lamination or separation of the panel components.
PART 2 - PRODUCTS
2.01 MATERIALS
- All panels shall be composite Stone Panels as manufactured by:
Stone Panels, Inc.
100 South Royal Lane
Carrollton, TX. 75006
Phone: (469) 635-5000
Toll Free: (800) 328-6275
Fax: (469) 635-5555
The architect will consider substitutions for the product specified only if performance
properties equal or exceed that which has been specified herein.
- The stone shall be ______________________________________________(stone name) with a
_________________________________________________ finish. (polished, honed, sandblasted,
flamed)
- All stone panels used in the work shall have the following properties.
- Facing: 3/16" (4.8mm) plus or minus 1/16" (1.6mm) natural stone polished,
honed, sandblasted or flamed finish.
- Reinforcing: 3/4" (19mm) aluminum honeycomb bonded by high strength epoxy
impregnated reinforced glass cloth.
- Thickness: 15/16" (24mm) plus or minus 1/16" (1.6mm)
- Average Weight: 3.3 lbs per sq. ft. (l6 kg per sq. m.)
- Dimensional Tolerance: Plus or minus 1/16" (1.6mm) in all directions. Plus or minus
1/16" (1.6mm) diagonally.
2.02 PERFORMANCE REQUIREMENTS
The stone panels shall meet the following performance properties confirmed by
independent laboratory testing.
- Acid-Freeze-Thaw by Wiss, Janney, Elstner Assoc.Test Method: Flexural strength loss not
to exceed 20% following 100 cycles + 170(F to -10(F while immersed in 4-pH sulfuric acid
solution.
- Large Missile Impact in accordance with Dade County Protocol PA 201-94: Resist large
missile impact fired at 50 ft. per second.
- Cyclic Wind Pressure Loading in accordance with Dade County Protocol PA 203-94: Resist
1342 repetitions of positive-negative 90 psf design wind pressure.
- ASTM E-84 Flame Spread: 5 maximum Smoke Development: 5 maximum Fuel Contributed: 0
- Toxicity Evaluation according to the University of Pittsburgh Test Method: No more toxic
than Douglas Fir wood.
- ASTM D-2015 Potential Heat of Combustion: 1150 BTU/lb. maximum.
- UBC 17-6 Multi-Story Fire Evaluation: Meet acceptance criteria.
- Modified ASTM E-108 Fire Evaluation: Resist 30 minute fire exposure.
- Flatwise Tension Bond Capacity: 385 psi following accelerated aging by rapid temperature
cycling from -40 degrees F to +160 degrees F.
- Flatwise Tension Bond Tests following ASTM C-67, Section 8 Freeze-Thaw: 290 psi flatwise
tension bond following 100 cycles freeze-thaw consisting of 20 hours freezing at 0 degrees
F and 4 hours thawing in water at 75 degrees F.
- ASTM E-72 Transverse Load Test: Average 215 lbs. per sq. ft. uniform load on 35.5 inch
simple span causing 0.49 inch deflection average.
- Racking Shear Load Tests: No disengagement nor major damage following application of
4,000 lb. load and 0.05" to 1.5" deflection on 8 ft. x 8 ft. specimen.
- ASTM E 283-73 Air Infiltration Test: Meet Criteria
ASTM E 331-86 Water Penetration Test: Meet Criteria
AAMA 501.1-83 Dynamic Water Penetration Test: Meet Criteria
2.03 ACCESSORIES
- Connection and anchorage hardware, including interlocking channels, anchor plates,
Z-sections, angle clips, structural silicone and threaded inserts shall be furnished and
installed under this contract. Such hardware shall be of sufficient size, thickness and
strength to properly support the panels and applied loads in a secure manner. All panel
fastening shall be completely concealed. All panel mounting details shall be approved by
Stone Panels, Inc. Technical Department prior to installation.
- Joint sealant materials specified in Section 07920 shall be tested for compatibility
with the natural stone facings specified.
PART 3 - EXECUTION
3.01 WORKMANSHIP
- Only experienced or composite panel manufacturer trained competent installers shall be
employed.
3.02 PREPARATION
- Assure that stud wall or subwall assembly is plumb, dimensioned according to Contract
Drawings and Shop Drawings, and installed in accordance with all pertinent codes and
regulations.
3.03 INSTALLATION
- Install all stone panels in accordance with instructions and recommendations as set
forth by the manufacturer, except to the extent more stringent requirements are indicated.
- Comply with all pertinent codes and regulations.
- All stone panels shall be installed in proper alignment in accordance with the Contract
Drawings and approved Shop Drawings.
3.04 CLEANING
- Clean all dirt, adhesives and sealant from panels using detergents or solvents as
appropriate and recommended by the manufacturer.
- Touch-up marred and chipped surfaces to match adjacent undamaged surfaces, as approved
by the Architect.
Download SPIspecs.doc - Word 97 file
Download SPIspecs.txt - Text file
Hold the SHIFT key down while clicking on the blue text above to save to your hard
drive.
You can also highlight the above text COPY it and then PASTE it into your document.
Please contact our Technical Services
Staff if you have any questions, would like additional information about our
Ultra-Lite Stone Panels, or would like us to work up details and pricing for your project.
World-Wide Suppliers of Ultra-Lite Stone
Panels
100 South Royal Lane
Coppell, TX 75019
Phone (469) 635-5000 / (800) 328-6275
Fax (469) 635-5555 / (800) 752-0783
Copyright © 1997, 1998, 1999, 2000, 2001 All Rights Reserved - Stone Panels, Inc.